Decode the Type 26 Voltage Probe Location and Status fields according to the SMBIOS 3.9.0 specification, section 7.27, "Voltage Probe (Type 26)". Table 95, "Voltage Probe: Location and Status fields", defines bits 4:0 as the Location field and bits 7:5 as the Status field. smbiosview was decoding these fields in the opposite order, causing the displayed voltage probe location and status to be swapped. Signed-off-by: Varshit Pandya <varshit.pandya@arm.com> |
||
|---|---|---|
| .. | ||